Health & Wellness Services

STUDY 8

Completed

INTRODUCTION

Since 2016, the Centers for Disease Control and Prevention (CDC) and European guidelines have recommended manual therapy as first- line treatment for MSK ill-health.  Manual therapy is an approach where Practitioners of Manual Therapy (PoMT) use hands-on data acquisition and analysis (HODA-A) as a measurement instrument for research, diagnosis, prognosis, and a tool for treatment.  Yet manual therapy techniques fail all reliability studies, therefore without proof that hands-on is a valid and reliable method of data collection, this very much limits the conclusions that can be drawn from using the hands in MSK healthcare.

HYPOTHESIS

Replicating experiment 6 methodology, this experiment focused on exploring Sensorimotor Memory Stimulation, investigating if attitudes or biases of tester’s during a MSK assessment disrupt the level of agreement and percentage correct outcomes of HODA-A.

RECRUITMENT

Twenty-eight healthy volunteers with recognised manual therapy qualifications (six men aged 38 ± 9.6 years and 22 women aged 43 ± 9.5 years) were recruited within a manual therapy learning institute. Of the volunteers, five men aged 35 ± 6.3 years and 12 women aged 41 ± 8 years, with 15 ± 8 years’ experience were randomly allocated to be tester’s.

Jo Abbott Blueprint Patient MSK Health Chat

Passive, supine leg length discrepancy test was used, to enable a valid assessment of structure due to minimal effects of gravity and fatigue on the testee’s MSK systems (Zink & Lawson, 1979). This strategy was used to make every effort to reduce extraneous variables, and therefore the measurement of each testee’s systems would be under basal conditions. The testers were required to palpate simultaneously the testee’s left and right medial malleoli’s and provide the relative spatial parameters of the leg lengths.

To test whether attitudes or biases of tester’s do trigger false alarms during HODA-A, the testers experimental criteria briefing was conducted in the presence of the testee’s. Post experiment, the testee’s were asked if the testers followed the experimental protocol that was presented to them. A percentage correct analysis was conducted on tester HODA-A outcomes, and further evaluation of the interview from the testee’s was used to support additional explanations to the outcomes. Furthermore, the examiner will remain observant to tester’s self-modification processes during this experiment, and, if possible, will capture, manipulate, and retest.

Prior to any data collection, the examiner set-up each testee in all studies to meet the specific criteria that had evolved from preceding experiments. A reflective journal was kept by the examiner noting observations from the testee’s and testers during each experiment. This reflection prevented any impaired memories when recalling the experience over a longer time frame (Almeida, 2005). The examiner oversaw all experiments, journaled any events that may be of interest, and analysed the final data submitted by the tester’s.

Plinths were far enough apart that data collection from each tester was blinded to the other testers’ data. Testee’s were barefoot and laid supine on the plinth. A ‘true’ result of the test condition was known to examiner. Once the experiment began, they were instructed not to fidget, talk, chew, or look around the room. The tester stood at the caudal end of the plinth, placed both hands around the testee’s ankles, such that their thumbs were level with the medial malleoli. They were instructed to bring the testee’s legs into the midline, without tugging the legs. The testers were instructed to use all five constructs of HODA-A to identify the testee’s leg length position in millimetres, noting which leg was longer and which leg was shorter. Blinded to one another, testers completed, and submitted, a data ticket.  The testers then moved to the next testee and only one round of testing was conducted.

Conclusion

There are factors within the sensorimotor memory stimulation of practitioners of manual therapy with more than 10 years clinical experience, that trigger false alarms when conducting a MSK assessment reducing HODA-A performance.

0 responses on "STUDY 8"

Leave a Message